HEAT TREATING - ISO9001:2015 CERTIFIED

We take great care in ensuring that all our parts are clean before heat treating. Cleanliness provides consistency and provides a better finish to your parts. Our polymer quenchent allows us to do more advanced heat treating and control cooling rates of your parts. The Swiss Lab Oven is great for all low temp work such as annealing, working to 1/2 Deg C. The L&L Oven is AMS Class 2 and works to 2400 Deg F. Solution heat treating and Hardness Testing is also available. 

 

HEAT TREATING & ANNEALING

  • L&L Heat treating oven  2400 DegF  AMS Class 2 (+/- 7 DegF conformity throughout oven ) (17″x12″x14″ interior size)

  • Water Soluble Polymer, Heated quench tank

  • Swiss lab oven capable of 275 DegC and 1/2 DegC consistency

  • Salt Bath Nitriding

HARDNESS TESTING

  • B and C Rockwell hardness testing available